ꯑꯥꯔ.ꯑꯦꯁ.꯴꯸꯵ ꯄꯤ.ꯑꯩꯆ
ꯃꯁꯤꯒꯤ RS485 pH ꯁꯦꯟꯁꯔ ꯑꯁꯤꯅꯥ ꯏꯟꯗꯁ꯭ꯠꯔꯤꯑꯦꯜ-ꯒ꯭ꯔꯦꯗ ꯍꯥꯏ-ꯄ꯭ꯔꯤꯁꯤꯁꯟ ꯄꯤ.ꯑꯩꯆ. ꯃꯁꯤꯅꯥ 0-14pHꯒꯤ ꯃꯄꯨꯡ ꯑꯣꯏꯕꯥ ꯃꯥꯄꯂꯒꯤ ꯔꯦꯟꯖ ꯑꯃꯥ ꯀꯣꯅꯁꯤꯜꯂꯤ, ꯃꯁꯤꯗꯥ 0.01pH ꯐꯥꯎꯕꯒꯤ ꯔꯤꯖꯣꯂꯨꯁꯟ ꯂꯩ ꯑꯃꯁꯨꯡ ±0.05pHꯒꯤ ꯃꯅꯨꯡꯗꯥ ꯂꯦꯡꯗꯕꯥ ꯃꯥꯄꯂꯒꯤ ꯑꯆꯨꯝꯕꯥ ꯂꯩ꯫ ꯃꯁꯤꯅꯥ ꯌꯥꯝꯅꯥ ꯊꯨꯅꯥ ꯔꯦꯁ꯭ꯄꯣꯟꯁ ꯁ꯭ꯄꯤꯗ ꯑꯃꯥ ꯄꯤꯔꯤ, ꯃꯁꯤꯅꯥ ꯐ꯭ꯂꯣꯌꯤꯡ ꯂꯤꯛꯌꯨꯏꯗ ꯑꯦꯅꯚꯥꯏꯔꯅꯃꯦꯟꯇ ꯑꯃꯗꯥ ꯁꯦꯀꯦꯟꯗ 10ꯗꯒꯤ ꯇꯥꯗꯅꯥ ꯁ꯭ꯇꯦꯕꯜ ꯗꯦꯇꯥ ꯑꯥꯎꯠꯄꯨꯠ ꯇꯧꯏ, ꯃꯁꯤꯅꯥ ꯔꯤꯑꯦꯜ-ꯇꯥꯏꯝ ꯑꯣꯅꯂꯥꯏꯟ ꯃꯣꯅꯤꯇꯔ ꯇꯧꯕꯒꯤ ꯑꯀꯅꯕꯥ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ ꯑꯗꯨ ꯐꯪꯍꯜꯂꯤ꯫ ꯗꯤꯚꯥꯏꯁ ꯑꯁꯤꯅꯥ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯃꯣꯗꯕꯁ ꯑꯥꯔ.ꯇꯤ.ꯌꯨ.ꯒꯤ ꯀꯝꯝꯌꯨꯅꯤꯀꯦꯁꯟ ꯄ꯭ꯔꯣꯇꯣꯀꯣꯜ ꯑꯁꯤ ꯑꯦꯗꯣꯞꯇ ꯇꯧꯏ, ꯃꯁꯤꯅꯥ ꯃꯤꯇꯔ ꯵꯰꯰ ꯐꯥꯑꯣꯕꯒꯤ ꯈ꯭ꯕꯥꯏꯗꯒꯤ ꯌꯥꯝꯕꯥ ꯇ꯭ꯔꯥꯟꯁꯃꯤꯁꯟ ꯗꯤꯁ꯭ꯇꯦꯟꯁ ꯂꯩꯕꯥ ꯑꯥꯔ.ꯑꯦꯁ.꯴꯸꯵ ꯏꯟꯇꯔꯐꯦꯁꯀꯤ ꯈꯨꯠꯊꯥꯡꯗꯥ ꯗꯦꯇꯥ ꯇ꯭ꯔꯥꯟꯁꯃꯤꯁꯟ ꯇꯧꯕꯥ ꯉꯃꯍꯜꯂꯤ꯫ ꯃꯁꯤꯅꯥ ꯑꯀꯅꯕꯥ ꯑꯦꯟꯇꯤ-ꯏꯟꯇꯔꯐꯦꯔꯦꯟꯁ ꯄꯔꯐꯣꯃꯦꯟꯁꯀꯤ ꯆꯥꯎꯊꯣꯀꯆꯕꯥ ꯄꯣꯀꯏ, PLC, DCS ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡ, ꯏꯟꯗꯁ꯭ꯠꯔꯤꯑꯦꯜ ꯀꯟꯠꯔꯣꯜ ꯁ꯭ꯛꯔꯤꯅꯁꯤꯡ ꯑꯃꯁꯨꯡ IoT ꯃꯣꯅꯤꯇꯔꯤꯡ ꯄ꯭ꯂꯦꯇꯐꯣꯔꯃꯁꯤꯡꯒꯥ ꯍꯀꯊꯦꯡꯅꯅꯥ ꯁꯝꯅꯕꯥ ꯌꯥꯏ, ꯃꯜꯇꯤ-ꯅꯣꯗ ꯅꯦꯇꯋꯥꯔꯀꯤꯡ ꯁꯄꯣꯔꯠ ꯇꯧꯏ, ꯏꯆꯝ ꯆꯝꯕꯥ ꯑꯃꯁꯨꯡ ꯏꯐꯤꯁꯤꯑꯦꯟꯇ ꯑꯣꯏꯕꯥ ꯋꯥꯏꯔꯤꯡꯒꯤ ꯐꯤꯆꯔꯁꯤꯡ ꯂꯩ, ꯑꯃꯁꯨꯡ ꯁꯤꯁ꯭ꯇꯦꯝ ꯏꯟꯇꯤꯒ꯭ꯔꯦꯁꯅꯒꯤ ꯃꯃꯜ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯍꯜꯂꯤ꯫
ꯑꯥꯔ.ꯑꯦꯁ.꯴꯸꯵ ꯄꯤ.ꯑꯩꯆ. ꯃꯁꯤꯅꯥ ꯊ꯭ꯔꯦꯗ ꯇꯧꯔꯕꯥ ꯏꯃꯔꯖꯦꯟꯁꯤ, ꯄꯥꯏꯄꯂꯥꯏꯟ ꯑꯃꯁꯨꯡ ꯐ꯭ꯂꯣ-ꯊ꯭ꯔꯨ ꯃꯈꯂꯁꯤꯡ ꯌꯥꯑꯣꯅꯥ ꯃꯁꯤꯡ ꯌꯥꯝꯂꯕꯥ ꯏꯅꯁ꯭ꯇꯣꯂꯦꯁꯟ ꯃꯦꯊꯗꯁꯤꯡ ꯁꯄꯣꯔꯠ ꯇꯧꯏ, ꯃꯁꯤꯗꯥ ꯈꯨꯗꯣꯡꯆꯥꯕꯥ ꯏꯅꯁ꯭ꯇꯣꯂꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯗꯤꯕꯒ ꯇꯧꯕꯥ ꯑꯃꯁꯨꯡ ꯅꯨꯃꯤꯠ ꯈꯨꯗꯤꯡꯒꯤ ꯐꯖꯅꯥ ꯃꯦꯟꯇꯤꯅꯦꯟꯁ ꯇꯧꯕꯥ ꯌꯥꯏ꯫


ꯄ꯭ꯔꯗꯛꯇꯀꯤ ꯃꯑꯣꯡ ꯃꯇꯧꯁꯤꯡ꯫
1. RS-485 ꯇ꯭ꯔꯥꯟꯁꯃꯤꯁꯟ ꯏꯟꯇꯔꯐꯦꯁ, MODBUS-RTU ꯀꯝꯝꯌꯨꯅꯤꯀꯦꯁꯟ ꯄ꯭ꯔꯣꯇꯣꯀꯣꯜ, ꯕꯥꯏꯗꯥꯏꯔꯦꯛꯁꯅꯦꯜ ꯀꯝꯝꯌꯨꯅꯤꯀꯦꯁꯟ ꯁꯄꯣꯔꯠ ꯇꯧꯕꯥ꯫
2. ꯏꯂꯦꯛꯠꯔꯤꯀꯦꯜ ꯁꯦꯐꯇꯤ ꯁꯣꯌꯗꯅꯥ ꯂꯩꯍꯟꯅꯕꯥ ꯑꯥꯏꯁꯣꯂꯦꯇꯦꯗ ꯄꯥꯋꯔ ꯁꯞꯂꯥꯏ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯠꯄꯨꯠ ꯗꯤꯖꯥꯏꯟ ꯇꯧꯕꯥ꯫
3. ꯀꯝꯞꯂꯦꯛꯁ ꯑꯦꯅꯚꯥꯏꯔꯅꯃꯦꯟꯇꯁꯤꯡꯒꯤꯗꯃꯛꯇꯥ ꯆꯨꯅꯕꯥ, ꯍꯦꯅꯒꯠꯂꯛꯂꯤꯕꯥ ꯑꯦꯟꯇꯤ-ꯏꯟꯇꯔꯐꯦꯔꯦꯟꯁ ꯀꯦꯄꯦꯕꯤꯂꯤꯇꯤꯒꯤꯗꯃꯛ ꯄ꯭ꯔꯣꯇꯦꯛꯁꯟ ꯁꯔꯛꯌꯨꯏꯠꯇꯥ ꯁꯦꯃꯈꯤꯕꯥ-꯫
4. ꯍꯦꯟꯅꯥ ꯏꯟꯇꯦꯂꯤꯖꯦꯟꯁꯀꯤꯗꯃꯛ ꯍꯦꯟꯅꯥ ꯏꯂꯦꯛꯠꯔꯣꯗ ꯗꯥꯏꯒ꯭ꯅꯣꯁ꯭ꯇꯤꯛ ꯏꯅꯐꯣꯔꯃꯦꯁꯟ ꯍꯦꯟꯅꯥ ꯄꯨꯊꯣꯀꯄꯥ ꯉꯝꯕꯥ, ꯏꯆꯝ ꯆꯝꯕꯥ ꯑꯃꯁꯨꯡ ꯌꯨꯖꯔ-ꯐ꯭ꯔꯦꯟꯗꯂꯤ ꯀꯝꯝꯌꯨꯅꯤꯀꯦꯁꯟ ꯄ꯭ꯔꯣꯇꯣꯀꯣꯜ꯫
5. ꯑꯦꯞꯂꯤꯀꯦꯁꯅꯁꯤꯡꯒꯤ ꯄꯥꯛ ꯆꯥꯎꯔꯕꯥ ꯔꯦꯟꯖ ꯑꯃꯥ ꯌꯥꯑꯣꯍꯟꯅꯕꯥ ꯂꯣ-ꯄꯥꯋꯔ ꯗꯤꯖꯥꯏꯟ; ꯏꯟꯇꯔꯅꯦꯜ ꯃꯦꯃꯣꯔꯤꯅꯥ ꯄꯥꯋꯔ ꯋꯥꯠꯄꯥ ꯃꯇꯃꯗꯥ ꯀꯦꯂꯤꯕ꯭ꯔꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯁꯦꯇꯤꯡꯁꯤꯡ ꯊꯝꯃꯤ꯫
꯶.ꯑꯀꯅꯕꯥ ꯀꯣꯔꯣꯁꯤꯟ ꯔꯦꯁꯤꯁ꯭ꯇꯦꯟꯁ ꯂꯩꯕꯥ ꯄꯤ.ꯄꯤ.ꯑꯦꯁ. ꯐꯖꯅꯥ ꯏꯅꯁ꯭ꯇꯣꯜ ꯇꯧꯅꯕꯒꯤꯗꯃꯛ ꯳/꯴-ꯏꯟꯆꯤꯒꯤ ꯃꯃꯥꯡ ꯑꯃꯁꯨꯡ ꯃꯇꯨꯡꯒꯤ ꯊꯣꯡꯁꯤꯡ꯫



ꯇꯦꯛꯅꯤꯀꯦꯜ ꯄꯦꯔꯥꯃꯤꯇꯔꯁꯤꯡ꯫
|
ꯄꯤ.ꯑꯩꯆ |
ꯆꯥꯡ |
꯰.꯰꯰ꯄꯤ.ꯑꯩꯆ.-꯱꯴.꯰꯰ꯄꯤ.ꯑꯩꯆ |
|
|
ꯋꯥꯔꯦꯞ |
꯰.꯰꯱ ꯄꯤ.ꯑꯩꯆ |
||
|
ꯆꯨꯝꯕꯒꯤ ꯆꯥꯡ |
±0.1 ꯄꯤ.ꯑꯩꯆ |
||
|
ꯑꯏꯪꯑꯁꯥ |
ꯆꯥꯡ |
-꯱꯰.꯰-꯱꯱꯰.꯰ ꯗꯤꯒ꯭ꯔꯤꯗꯥ ꯂꯩ꯫ |
|
|
ꯋꯥꯔꯦꯞ |
꯰.꯱ ꯗꯤꯒ꯭ꯔꯤꯗꯥ ꯂꯩ꯫ |
||
|
ꯆꯨꯝꯕꯒꯤ ꯆꯥꯡ |
±0.5 ꯗꯤꯒ꯭ꯔꯤ ꯑꯣꯏ꯫ |
||
|
ꯁꯦꯟꯁꯔ ꯃꯈꯜ꯫ |
ꯊꯥꯔꯃꯤꯁ꯭ꯇꯔ ꯇꯤ.ꯑꯩꯆ.꯱꯰ꯀꯦ |
||
|
ꯀꯝꯄꯦꯟꯁꯦꯁꯟ ꯄꯤꯕꯥ꯫ |
ꯑꯣꯇꯣꯃꯦꯇꯤꯛ/ꯃꯦꯅꯨꯑꯦꯜ ꯑꯣꯏꯕꯥ꯫ |
||
|
ꯗꯦꯇꯥ ꯇ꯭ꯔꯥꯟꯁꯃꯤꯁꯟ ꯇꯧꯕꯥ꯫ |
ꯑꯥꯔ.ꯑꯦꯁ.-꯴꯸꯵ ꯑꯃꯁꯨꯡ ꯑꯦꯟ |
MODBUS-RTU ꯀꯝꯝꯌꯨꯅꯤꯀꯦꯁꯟ ꯄ꯭ꯔꯣꯇꯣꯀꯣꯜ |
|
|
ꯑꯇꯣꯞꯄꯥ ꯄꯦꯔꯥꯃꯤꯇꯔꯁꯤꯡ꯫ |
ꯄꯥꯋꯔ ꯁꯞꯂꯥꯏ ꯇꯧꯕꯥ꯫ |
꯹~꯲꯷ꯚꯤ.ꯗꯤ.ꯁꯤ |
|
|
ꯑꯥꯏꯁꯣꯂꯦꯁꯟ ꯇꯧꯕꯥ꯫ |
꯲꯵꯰꯰ꯚꯤ.ꯑꯥꯔ.ꯑꯦꯝ |
||
|
ꯄꯥꯋꯔ ꯀꯟꯖꯨꯃꯁꯟ ꯇꯧꯕꯥ꯫ |
ꯆꯥꯎꯔꯥꯛꯅꯥ. 0.5ꯋꯥꯏ |
||
|
ꯃꯆꯥꯛ |
ꯄꯤ.ꯄꯤ.ꯑꯦꯁ.ꯀꯤ ꯍꯥꯎꯖꯤꯡ꯫ |
ꯄ꯭ꯔꯗꯛꯇ ꯑꯦꯞꯂꯤꯀꯦꯁꯟ꯫








ꯑꯦꯐ.ꯑꯦ.ꯀ꯭ꯌꯨ
ꯋꯥꯍꯪ : ꯑꯗꯣꯃꯒꯤ ꯐꯦꯛꯇꯔꯤꯗꯥ ꯆꯠꯄꯥ ꯌꯥꯕꯔꯥ?
ꯎ: ꯑꯩꯈꯣꯌꯒꯤ ꯀꯝꯄꯦꯅꯤ ꯑꯁꯤ ꯆꯥꯏꯅꯥꯒꯤ ꯁꯉ꯭ꯒꯣꯃꯗꯥ ꯂꯩ, ꯑꯩꯈꯣꯌꯗꯥ ꯂꯥꯀꯄꯥ ꯑꯁꯤ ꯌꯥꯝꯅꯥ ꯈꯨꯗꯣꯡꯆꯥꯕꯥ ꯑꯃꯅꯤ꯫ꯑꯗꯨꯒꯥ ꯃꯥꯂꯦꯝ ꯄꯨꯝꯕꯒꯤ ꯀ꯭ꯂꯥꯏꯟꯇ ꯈꯨꯗꯤꯡꯃꯛ ꯑꯩꯈꯣꯌꯗꯥ ꯌꯥꯝꯅꯥ ꯇꯔꯥꯝꯅꯥ ꯑꯣꯛꯂꯤ꯫
ꯋꯥꯍꯪ : ꯃꯃꯂꯒꯤ ꯃꯇꯥꯡꯗꯥ?
ꯎ: ꯃꯃꯜ ꯑꯁꯤ ꯋꯥꯔꯤ ꯁꯥꯅꯕꯥ ꯌꯥꯏ꯫ꯃꯁꯤ ꯑꯗꯣꯃꯒꯤ ꯃꯁꯤꯡꯒꯤ ꯃꯇꯨꯡ ꯏꯟꯅꯥ ꯍꯣꯡꯗꯣꯀꯄꯥ ꯌꯥꯏ꯫ ꯑꯗꯣꯝꯅꯥ ꯋꯥꯍꯪ ꯑꯃꯥ ꯍꯪꯂꯀꯄꯥ ꯃꯇꯃꯗꯥ,ꯑꯗꯣꯝꯅꯥ ꯄꯥꯝꯂꯤꯕꯥ ꯃꯁꯤꯡ ꯑꯗꯨ ꯑꯩꯈꯣꯌꯗꯥ ꯈꯉꯍꯅꯕꯤꯌꯨ꯫
ꯋꯥꯍꯪ : ꯑꯩꯈꯣꯌꯗꯒꯤ ꯀꯔꯤ ꯂꯧꯕꯥ ꯌꯥꯕꯒꯦ?
ꯎ: ꯀꯟꯠꯔꯣꯂꯔ, ꯗꯤꯖꯤꯇꯦꯜ ꯏꯂꯦꯛꯠꯔꯤꯗ, ꯇꯦꯁ꯭ꯠ ꯄꯦꯟ, ꯁꯦꯟꯁꯔ, ꯏꯁꯤꯡꯒꯤ ꯀ꯭ꯕꯥꯂꯤꯇꯤ ꯁꯦꯟꯁꯔ꯫
ꯍꯠ ꯇꯦꯒꯁ: rs485 ph ꯁꯦꯟꯁꯔ, ꯆꯥꯏꯅꯥ rs485 ph ꯁꯦꯟꯁꯔ ꯃꯦꯟꯌꯨꯐꯦꯀꯆꯔꯔꯁꯤꯡ, ꯐꯦꯛꯇꯔꯤ꯫


